Ultramag PRO

Ultramag PRO

Ultrasonic complexes type G10-G400

Purpose:

Gas volume measuring systems are designed to measure the working volume of natural gas according to GOST 5542, free petroleum gas according to GOST R 8.615, other gases and automatically convert the measured gas volume to standard conditions depending on pressure and/or temperature, gas compressibility factor. Scope: commercial and technological gas metering at public utilities and industrial enterprises, gas distribution points and boiler houses.

Number in the SI register 93944-24. MPI 4 years. DNRG 407 221-722 TU. Example of designation when ordering: Ultramag PRO BA-M-1A-PTZ-DN50-G65-A1 (1:400; δ var.1; L) with pressure channel setting to 0.6 MPa)) Number in the SI register 58524-14 with amendment 23. MPI 4 years. SYAMI 407 259-671 TU. Example of order entry: Ultramag-50-G25-1:200-1-1A-L-M (with pressure channel setting to 0.6 MPa) Number in the SI register 82240-21. MPI 2 years. SYAMI 407 259-722 TU. Example of order entry: Ultramag-M-50-G25-1:200-1-1A-L (with pressure channel setting to 0.6 MPa)

Methods for calculating the compressibility factor:
~natural gas according to GOST 30319.2-2015, GOST 30319.3-2015, using the AGA8 equation of state;
~free petroleum gas, nitrogen, air, carbon dioxide, inert gases using GSSSD data
Total relative error in bringing the working volume of gas to standard conditions:
~option 1
~ ± 2% – in the flow rate range from Qmin. to 0.05 Qmax
~ ± 1% – in the flow rate range from 0.05 Qmax. to Qmax
~option 2
~ ± 2.3% – in the flow rate range from Qmin. to 0.05 Qmax
~ ± 1.3% – in the flow rate range from 0.05 Qmax. to Qmax
~option 3
~ ± 1.5% – in the flow rate range from Qmin. up to 0.05 Qmax.
~ ± 1% – in the flow range from 0.05 Qmax. to Qmax
Relative error:
~pressure measurement channel does not exceed ± 0.4% (± 0.25% on request)
~temperature measurement channel does not exceed ± 0.1%
~correction coefficient does not exceed ± 0.5% (± 0.3% on request)
Operation at pressure from 0 to 1.6 MPa
Ambient temperature measurement range from -40 ° C to + 60 ° C
Gas temperature measurement range from -40 ° C to + 60 ° C
Dynamic flow measurement range up to 1:400
Explosion protection marking 1Ex ib IIB T4 Gb X
Degree of protection IP 66

Horizontal and vertical installation on the pipeline. Deviation from the horizontal and vertical does not affect the metrological characteristics.
Local resistance of pipelines and shut-off valves does not affect the measurement error of the complex in the presence of straight sections of 5DN / 3DN.
For technological metering, meters can be used with straight sections of 2DN / 2DN, subject to the established installation rules, with an error of within ± 5% (without registration of SI).
Calibration of the pressure measurement channel in the range of 1:11.
Resistant to sudden pressure changes in the pipeline.
Increased archive depth of up to 16,000 records.
Autonomous power supply. The inter-
verification interval is 4 years
. Low-frequency output. 4-20 mA interface on request.
Parallel operation of optical, RS-485 and RS-232 interfaces.
Compatibility with various telemetry systems (IUS-Tsifra, Gazset, etc.).
User-friendly software interface .
Affordable price.