Ultramag PRO RT
Ultramag PRO RT
Ultrasonic single-beam complexes G10…G100 DN 50 and 80 mm instead of a rotary counter
Purpose:
ULTRAMAG RT matches the overall length and requirements of DN 50 and 80 mm rotary meters. The system can be installed to replace existing rotary meters or systems. Straight sections are not required. Gas volume measurement systems are designed to measure the working volume of natural gas according to GOST 5542, free petroleum gas according to GOST R 8.615, and other gases in networks with pressures up to 1.2 MPa, and automatically convert the measured gas volume to standard conditions depending on temperature, pressure, and gas compressibility.
Application area: commercial and process gas metering at utilities and industrial facilities, gas distribution points, and boiler houses with pressures up to 1.2 MPa and flow rates up to 100 m³/hour. SI register number 93944-24. MPI 4 years. DNRG407 259-722 TU. Example of designation when ordering: Ultramag PRO RT-M-1A-PTZ-DN50-G65-A1 (1:200; δ var. 1; L) with pressure channel setting to 0.6 MPa)) Number in the register of SI 58524-14 with amendment 23. MPI 4 years. SYAM 407 259-671 TU. Example of entry when ordering: Ultramag-50-G25-1:200-1-1A-L-M-RT (with pressure channel setting to 0.6 MPa)
Methods for calculating the compressibility
factor:
~natural gas
according to GOST 30319.2-2015, GOST 30319.3-2015, using
the AGA8 equation of state;
~free petroleum gas, nitrogen, air, carbon
dioxide, inert gases using GSSSD data
Total relative error in bringing the working
volume of gas to standard conditions:
~option 1
~ ± 2%
– in the flow rate range from Qmin. to 0.05
Qmax
~ ± 1% – in the
flow rate range from 0.05 Qmax. to
Qmax
~option
2
~ ± 2.3% – in the
flow rate range from Qmin. to 0.05
Qmax
~ ± 1.3% – in
the flow rate range from 0.05 Qmax. to
Qmax
~option
3
~ ± 1.5% – in the
flow rate range from Qmin. up to 0.05
Qmax.
~ ± 1% – in the
flow range from 0.05 Qmax. to Qmax
Relative error:
~ pressure measurement channel does not
exceed ± 0.4% (± 0.25% on request)
~ temperature measurement channel does not
exceed ± 0.1%
~ correction
factor does not exceed ± 0.5% (± 0.3% on
request)
Operation at
pressure from 0 to 1.6 MPa
Ambient temperature measurement range from
-40 ° C to + 60 ° C
Gas
temperature measurement range from -40 ° C to + 60 °
C
Dynamic flow measurement
range up to 1:200
Explosion
protection marking 1Ex ib IIB T4 Gb X
Degree of protection IP 66
Installation instead of rotary meters and
complexes without welding
Local resistance of pipelines and shut-off
valves does not affect the measurement error of the
complex
Straight sections
are not required!!! 0DN/0DN
Resistant to sudden pressure changes in the
pipeline
Calibration of the
pressure measurement channel in the range of
1:11
Resistant to sudden
pressure changes in the pipeline
Increased archive depth up to 16,000
records
Autonomous power
supply
Inter-verification
interval of 4 years
Low-frequency output. Interface 4-20 mA on
request
Parallel operation
of optical, RS-485 and RS-232
interfaces
Compatible with
various telemetry systems (IUS-Tsifra, Gazset,
etc.)
User-friendly
software interface
Affordable price